WT278 - Uni Eindhoven - Niederlande
WT334 - Uni Bundeswehr München - Deutschland
WT327 - Ammonit Wind Tunnel - Deutschland
WT341 - Airbus Warschau - Polen
WT278 - Uni Eindhoven - Niederlande
WT278 - Uni Eindhoven - Niederlande
WT307 - TH Köln - Deutschland
WT342 - INTA Madrid - Spanien
WT342 - Uni Wollogong - Australien

WT277 (60 m/s) Uni Hamm-Lippstadt

Referenceproject WT277

University of Applied Sciences Hamm-Lippstadt
For the University of Applied Sciences (Contact: Heinrich Teichrieb, Prof. Dr. Kiuntke) the Windtunnel WT277 was built. The wind tunnel is characterized by a high contraction, the non-expanding corners as well as the long diffuser and the low degree of turbulence.


Highlights
  • High contraction of 11
  • Non-expanding corners
  • Long diffuser
  • Very good turbulence level
  • Very good price-performance ratio                                             
WT 277 Icon Lippstadt

Productdescription
Basic structure
The WT277 consists of a steel profile welded construction and galvanized sheet metal. The additional painting gives the wind tunnel an attractive appearance and is also protected against corrosion. Large manholes in all relevant segments make it easy to enter the inside of the wind tunnel.
Drive
The WT277 is driven by a vibration-decoupled axial fan. The fan, which is mounted on spring shock absorbers, is connected to the wind tunnel via canvas flanges. This ensures low-noise plant operation. The Nanzelle and the guiding vanes are matched to the fan in order to generate a flow with reduced swirl.
Flow preparation
The long diffusers, whose narrow opening angle counteracts flow separation, open into non-expanding corners. The wind tunnel has an extra large sieve chamber. This contains four sieves at an optimal distance from one another. These non-split stainless steel sieves are accessible via manholes for easy cleaning. A honeycomb straightener with a length-to-diameter ratio of 8: 1 further reduces the swirl of the flow. In a nozzle, the nozzle geometry of which corresponds to a polynomial of the fifth order, the flow is prepared and any turbulence that may be present is suppressed.
Measurement
The measurement in the wind tunnel can be carried out with an open as well as with a closed test section. An ergonomic conversion of the test section is possible via a flange connection to the nozzle. Both open and closed test sections can be equipped with a wind tunnel scale if required. The open test section has a flow collecting funnel to reduce the flow losses during the measurement. The inside of the closed test section can be seen through glass windows. The recording of flow characteristics using optical measurement methods, e.g. PIV (Particle Image Velocimetry) or LDA (Laser Doppler Anemometry) is possible without any problems.
Control
The wind tunnel is controlled intuitively and safely via a touch display. After specifying the target wind speed, the wind speed, speed or dynamic pressure is regulated.


Characteristics
Closed test section
Design type Closed loop, standing              
Measuring cross section 600 x 600 mm
Measuring length 1500 mm
Top speed 60 m/s
Turbulence level 0,4 %
Datasheet WT277 with closed testsection

Closed testsection
Design type Closed loop, standing              
Measuring cross section
600 x 600 mm
Measuring length 900
Top speed
50 m/s
Turbulence level 0,8 %
Datasheet WT277 with open testsection


Gallery



WT277 Abmae

WT277 Bild1

WT277 Bild2

No records found.